PM-M12S-04P-MM-SL8A01
20030000843
Sensor/Actuator Cable,PVC,black,UL2517,Male plug,Straight M12,Coding S,Unshielded,Trimming cable end,Cable Cable length:1m
- 04
- Panoramica
- Dati tecnici
- Accessori
- Certificazione
- Dati aziendali
- Scarica
Certificazione del prodotto
Vantaggi del prodotto
☑Sealing optimization, protection level up to IP68☑Meet the harsh environment
☑Suitable for various occasions connection technology
☑Compatible with the international and domestic same series products
- Modello 3D
- Environmental conditions
- General parameters
- Material
- Standards and specifications
- Cable
- Dimension
Modello 3D
Environmental conditions
Ambient temperature | -25℃...80℃ |
IP class | IP68 |
General parameters
Rated current | 12A |
630V | |
Number of potentials | 4 |
Insulation resistance | ≥ 100 MΩ |
Error-proof coding | S-Code |
Overvoltage level | Ⅲ |
Pollution level | 3 |
Insertion and pullout cycle | ≥ 100 |
Torque | 0.4 Nm |
Material
Flammability rating ,in line with UL94 | V0 |
Contact material | CuZn |
Material contact surface | Au |
Contact carrier material | PU |
Coil material | Zinc alloy, nickel plated |
Sealing material | Silicon |
Standards and specifications
Standards/specifications | IEC 61076-2-111 |
Cable
Cable type | PVC Black |
Cable type(abbreviation) | PVC |
UL AWM form | UL2570 |
Cross section | 1.31mm² |
AWG signal wire | 16AWG |
Wire structure Signal wire | 26/0.254mm² |
Core diameter (including insulation layer) | 3.1±0.05mm |
Wire color | 1 Black1 2 Black2 3 Black3 PE Yellow /Green |
Thickness, insulation | 0.68mm |
Cable outer diameter D | 9.2mm |
Minimum bend radius ,fixed installation | 5*OD |
Minimum bend radius ,mobile installation | 10*OD |
Bending radius | 50.8mm |
Cable weight | 136kg/km |
Outer sheath, material | PVC |
Conductor insulation material | PVC |
Conductor material | Tinned copper |
Insulation resistance | 10MΩ |
Conductor resistance | Maximum 14.6Ω/km (at 20 °C) ) |
Nominal cable voltage | 1000V |
Cable test voltage | 2000V |
Special attributes | Silicone-free |
Flame retardant | VW-1 |
Other protection functions | Anti-UV |
Dimension
Cable length | 1m |
Accessories
Sealing cap | CAP-M12-FP-8001 |
numero d'ordine | 20030000843 |
Unità di imballaggio | / |
Quantità di ordine minimo | 100 |
Peso dei prodotti (senza imballaggio) | / |
Parti corrispondenti
- Tutti i prodotti di supporto(8)